Added comments.
Fix a label.
This commit is contained in:
48
plugin.py
48
plugin.py
@ -96,6 +96,8 @@ class BasePlugin:
|
|||||||
self.phase_angle=Average()
|
self.phase_angle=Average()
|
||||||
# Frequency for last 5 minutes
|
# Frequency for last 5 minutes
|
||||||
self.frequency=Average()
|
self.frequency=Average()
|
||||||
|
|
||||||
|
# Used only when Moredata is set...
|
||||||
# Total demand power for last 5 minutes
|
# Total demand power for last 5 minutes
|
||||||
self.total_demand_power=Average()
|
self.total_demand_power=Average()
|
||||||
# Import demand power for last 5 minutes
|
# Import demand power for last 5 minutes
|
||||||
@ -146,9 +148,11 @@ class BasePlugin:
|
|||||||
if 6 not in Devices:
|
if 6 not in Devices:
|
||||||
Options = { "Custom": "1;PF" }
|
Options = { "Custom": "1;PF" }
|
||||||
Domoticz.Device(Name="Power Factor", Unit=6, TypeName="Custom", Used=0, Options=Options).Create()
|
Domoticz.Device(Name="Power Factor", Unit=6, TypeName="Custom", Used=0, Options=Options).Create()
|
||||||
|
if Parameters["Mode5"] == "Moredata":
|
||||||
if 7 not in Devices:
|
if 7 not in Devices:
|
||||||
Options = { "Custom": "1;Deg" }
|
Options = { "Custom": "1;Deg" }
|
||||||
Domoticz.Device(Name="Phase Angle", Unit=7, TypeName="Custom", Used=0, Options=Options).Create()
|
Domoticz.Device(Name="Phase Angle", Unit=7, TypeName="Custom", Used=0, Options=Options).Create()
|
||||||
|
|
||||||
if 8 not in Devices:
|
if 8 not in Devices:
|
||||||
Options = { "Custom": "1;Hz" }
|
Options = { "Custom": "1;Hz" }
|
||||||
Domoticz.Device(Name="Frequency", Unit=8, TypeName="Custom", Used=0, Options=Options).Create()
|
Domoticz.Device(Name="Frequency", Unit=8, TypeName="Custom", Used=0, Options=Options).Create()
|
||||||
@ -183,7 +187,7 @@ class BasePlugin:
|
|||||||
Domoticz.Device(Name="Maximum Total Demand Current", Unit=20, TypeName="Current (Single)", Used=0).Create()
|
Domoticz.Device(Name="Maximum Total Demand Current", Unit=20, TypeName="Current (Single)", Used=0).Create()
|
||||||
|
|
||||||
if 21 not in Devices:
|
if 21 not in Devices:
|
||||||
Domoticz.Device(Name="Total Energy (Active)", Unit=21, Type=0xfa, Subtype=0x01, Used=0).Create()
|
Domoticz.Device(Name="Total Energy", Unit=21, Type=0xfa, Subtype=0x01, Used=0).Create()
|
||||||
# 22 will not be used Total Energy (Reactive)
|
# 22 will not be used Total Energy (Reactive)
|
||||||
|
|
||||||
return
|
return
|
||||||
@ -205,7 +209,9 @@ class BasePlugin:
|
|||||||
Devices[4].Update(1, "0")
|
Devices[4].Update(1, "0")
|
||||||
Devices[5].Update(1, "0")
|
Devices[5].Update(1, "0")
|
||||||
Devices[6].Update(1, "0")
|
Devices[6].Update(1, "0")
|
||||||
|
if Parameters["Mode5"] == "Moredata":
|
||||||
Devices[7].Update(1, "0")
|
Devices[7].Update(1, "0")
|
||||||
|
|
||||||
Devices[8].Update(1, "0")
|
Devices[8].Update(1, "0")
|
||||||
Devices[9].Update(1, "0")
|
Devices[9].Update(1, "0")
|
||||||
Devices[10].Update(1, "0")
|
Devices[10].Update(1, "0")
|
||||||
@ -221,38 +227,40 @@ class BasePlugin:
|
|||||||
|
|
||||||
Devices[21].Update(1, "0")
|
Devices[21].Update(1, "0")
|
||||||
|
|
||||||
#Domoticz.Log("Voltage : " + str(getmodbus(0x0000, client)) )
|
# Voltage
|
||||||
self.voltage.update(getmodbus(0x0000, client))
|
self.voltage.update(getmodbus(0x0000, client))
|
||||||
Devices[1].Update(1, self.voltage.strget())
|
Devices[1].Update(1, self.voltage.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Current : " + str(getmodbus(0x0006, client)) )
|
# Current
|
||||||
self.current.update(getmodbus(0x0006, client))
|
self.current.update(getmodbus(0x0006, client))
|
||||||
Devices[2].Update(1, self.current.strget())
|
Devices[2].Update(1, self.current.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Power Active : " + str(getmodbus(0x000c, client)) )
|
# Power (Active)
|
||||||
self.active_power.update(getmodbus(0x000c, client))
|
self.active_power.update(getmodbus(0x000c, client))
|
||||||
Devices[3].Update(1, self.active_power.strget())
|
Devices[3].Update(1, self.active_power.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Power apparent: " + str(getmodbus(0x0012, client)) )
|
# Power (Apparent)
|
||||||
self.apparent_power.update(getmodbus(0x0012, client))
|
self.apparent_power.update(getmodbus(0x0012, client))
|
||||||
Devices[4].Update(1, self.apparent_power.strget())
|
Devices[4].Update(1, self.apparent_power.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Power reactive: " + str(getmodbus(0x0018, client)) )
|
# Power (Reactive)
|
||||||
self.reactive_power.update(getmodbus(0x0018, client))
|
self.reactive_power.update(getmodbus(0x0018, client))
|
||||||
Devices[5].Update(1, self.reactive_power.strget())
|
Devices[5].Update(1, self.reactive_power.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Power Factor : " + str(getmodbus(0x001e, client)) )
|
# Power Factor
|
||||||
self.power_factor.update(getmodbus(0x001e, client))
|
self.power_factor.update(getmodbus(0x001e, client))
|
||||||
Devices[6].Update(1, self.power_factor.strget())
|
Devices[6].Update(1, self.power_factor.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Phase Angle : " + str(getmodbus(0x0024, client)) )
|
if Parameters["Mode5"] == "Moredata":
|
||||||
|
# Phase Angle
|
||||||
self.phase_angle.update(getmodbus(0x0024, client))
|
self.phase_angle.update(getmodbus(0x0024, client))
|
||||||
Devices[7].Update(1, self.phase_angle.strget())
|
Devices[7].Update(1, self.phase_angle.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Frequency : " + str(getmodbus(0x0046, client)) )
|
# Frequency
|
||||||
self.frequency.update(getmodbus(0x0046, client))
|
self.frequency.update(getmodbus(0x0046, client))
|
||||||
Devices[8].Update(1, self.frequency.strget())
|
Devices[8].Update(1, self.frequency.strget())
|
||||||
|
|
||||||
|
# For Imported/Exported Energy (Active) and the last P1 Counter
|
||||||
power = self.active_power.get()
|
power = self.active_power.get()
|
||||||
if power >= 0:
|
if power >= 0:
|
||||||
import_power = power
|
import_power = power
|
||||||
@ -264,45 +272,45 @@ class BasePlugin:
|
|||||||
else:
|
else:
|
||||||
export_power = 0
|
export_power = 0
|
||||||
|
|
||||||
#Domoticz.Log("Import NRJ act : " + str(getmodbus(0x0048, client)) )
|
# Imported Energy (Active)
|
||||||
import_e = str(getmodbus(0x0048, client)*1000)
|
import_e = str(getmodbus(0x0048, client)*1000)
|
||||||
Devices[9].Update(1, sValue=str(import_power)+";"+import_e)
|
Devices[9].Update(1, sValue=str(import_power)+";"+import_e)
|
||||||
|
|
||||||
#Domoticz.Log("Export NRJ act : " + str(getmodbus(0x004a, client)) )
|
# Exported Energy (Active)
|
||||||
export_e = str(getmodbus(0x004a, client)*1000)
|
export_e = str(getmodbus(0x004a, client)*1000)
|
||||||
Devices[10].Update(1, sValue=str(export_power)+";"+export_e)
|
Devices[10].Update(1, sValue=str(export_power)+";"+export_e)
|
||||||
|
|
||||||
if Parameters["Mode5"] == "Moredata":
|
if Parameters["Mode5"] == "Moredata":
|
||||||
#Domoticz.Log("Total Demand Pwr : " + str(getmodbus(0x0054, client)) )
|
# Total Demand Powier (Active)
|
||||||
self.total_demand_power.update(getmodbus(0x0054, client))
|
self.total_demand_power.update(getmodbus(0x0054, client))
|
||||||
Devices[13].Update(1, self.total_demand_power.strget())
|
Devices[13].Update(1, self.total_demand_power.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Max Demand Pwr : " + str(getmodbus(0x0056, client)) )
|
# Maximum Total Demand Power (Active)
|
||||||
Devices[14].Update(1, str(getmodbus(0x0056, client)))
|
Devices[14].Update(1, str(getmodbus(0x0056, client)))
|
||||||
|
|
||||||
#Domoticz.Log("Input Demand Pwr : " + str(getmodbus(0x0058, client)) )
|
# Import Demand Power (Active)
|
||||||
self.import_demand_power.update(getmodbus(0x0058, client))
|
self.import_demand_power.update(getmodbus(0x0058, client))
|
||||||
Devices[15].Update(1, self.import_demand_power.strget())
|
Devices[15].Update(1, self.import_demand_power.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Max Input Demand Pwr : " + str(getmodbus(0x005a, client)) )
|
# Maximum Import Demand Power (Active)
|
||||||
Devices[16].Update(1, str(getmodbus(0x005a, client)))
|
Devices[16].Update(1, str(getmodbus(0x005a, client)))
|
||||||
|
|
||||||
#Domoticz.Log("Export Demand Pwr : " + str(getmodbus(0x005c, client)) )
|
# Export Demand Power (Active)
|
||||||
self.import_demand_power.update(getmodbus(0x0058, client))
|
self.import_demand_power.update(getmodbus(0x0058, client))
|
||||||
Devices[17].Update(1, self.import_demand_power.strget())
|
Devices[17].Update(1, self.import_demand_power.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Max Export Demand Pwr : " + str(getmodbus(0x005e, client)) )
|
# Maxium Export Demand Power (Active)
|
||||||
Devices[18].Update(1, str(getmodbus(0x005e, client)))
|
Devices[18].Update(1, str(getmodbus(0x005e, client)))
|
||||||
|
|
||||||
#Domoticz.Log("Total Demand Cur: " + str(getmodbus(0x0102, client)) )
|
# Total Demand Current
|
||||||
self.total_demand_current.update(getmodbus(0x0102, client))
|
self.total_demand_current.update(getmodbus(0x0102, client))
|
||||||
Devices[19].Update(1, self.total_demand_current.strget())
|
Devices[19].Update(1, self.total_demand_current.strget())
|
||||||
|
|
||||||
#Domoticz.Log("Max Total Demand Cur: " + str(getmodbus(0x0108, client)) )
|
# Maxium Total Demand Current
|
||||||
Devices[20].Update(1, str(getmodbus(0x0108, client)))
|
Devices[20].Update(1, str(getmodbus(0x0108, client)))
|
||||||
|
|
||||||
|
|
||||||
#Domoticz.Log("Total Energy Act: " + str(getmodbus(0x0156, client)) )
|
# P1 Counter with import and export values
|
||||||
Devices[21].Update(1, sValue=import_e+";0;"+export_e+";0;"+str(import_power)+";"+str(export_power))
|
Devices[21].Update(1, sValue=import_e+";0;"+export_e+";0;"+str(import_power)+";"+str(export_power))
|
||||||
|
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue