Added comments.

Fix a label.
This commit is contained in:
2022-10-23 21:44:17 +02:00
parent b6a4f22721
commit cefb281872

View File

@ -96,6 +96,8 @@ class BasePlugin:
self.phase_angle=Average()
# Frequency for last 5 minutes
self.frequency=Average()
# Used only when Moredata is set...
# Total demand power for last 5 minutes
self.total_demand_power=Average()
# Import demand power for last 5 minutes
@ -146,9 +148,11 @@ class BasePlugin:
if 6 not in Devices:
Options = { "Custom": "1;PF" }
Domoticz.Device(Name="Power Factor", Unit=6, TypeName="Custom", Used=0, Options=Options).Create()
if Parameters["Mode5"] == "Moredata":
if 7 not in Devices:
Options = { "Custom": "1;Deg" }
Domoticz.Device(Name="Phase Angle", Unit=7, TypeName="Custom", Used=0, Options=Options).Create()
if 8 not in Devices:
Options = { "Custom": "1;Hz" }
Domoticz.Device(Name="Frequency", Unit=8, TypeName="Custom", Used=0, Options=Options).Create()
@ -183,7 +187,7 @@ class BasePlugin:
Domoticz.Device(Name="Maximum Total Demand Current", Unit=20, TypeName="Current (Single)", Used=0).Create()
if 21 not in Devices:
Domoticz.Device(Name="Total Energy (Active)", Unit=21, Type=0xfa, Subtype=0x01, Used=0).Create()
Domoticz.Device(Name="Total Energy", Unit=21, Type=0xfa, Subtype=0x01, Used=0).Create()
# 22 will not be used Total Energy (Reactive)
return
@ -205,7 +209,9 @@ class BasePlugin:
Devices[4].Update(1, "0")
Devices[5].Update(1, "0")
Devices[6].Update(1, "0")
if Parameters["Mode5"] == "Moredata":
Devices[7].Update(1, "0")
Devices[8].Update(1, "0")
Devices[9].Update(1, "0")
Devices[10].Update(1, "0")
@ -221,38 +227,40 @@ class BasePlugin:
Devices[21].Update(1, "0")
#Domoticz.Log("Voltage : " + str(getmodbus(0x0000, client)) )
# Voltage
self.voltage.update(getmodbus(0x0000, client))
Devices[1].Update(1, self.voltage.strget())
#Domoticz.Log("Current : " + str(getmodbus(0x0006, client)) )
# Current
self.current.update(getmodbus(0x0006, client))
Devices[2].Update(1, self.current.strget())
#Domoticz.Log("Power Active : " + str(getmodbus(0x000c, client)) )
# Power (Active)
self.active_power.update(getmodbus(0x000c, client))
Devices[3].Update(1, self.active_power.strget())
#Domoticz.Log("Power apparent: " + str(getmodbus(0x0012, client)) )
# Power (Apparent)
self.apparent_power.update(getmodbus(0x0012, client))
Devices[4].Update(1, self.apparent_power.strget())
#Domoticz.Log("Power reactive: " + str(getmodbus(0x0018, client)) )
# Power (Reactive)
self.reactive_power.update(getmodbus(0x0018, client))
Devices[5].Update(1, self.reactive_power.strget())
#Domoticz.Log("Power Factor : " + str(getmodbus(0x001e, client)) )
# Power Factor
self.power_factor.update(getmodbus(0x001e, client))
Devices[6].Update(1, self.power_factor.strget())
#Domoticz.Log("Phase Angle : " + str(getmodbus(0x0024, client)) )
if Parameters["Mode5"] == "Moredata":
# Phase Angle
self.phase_angle.update(getmodbus(0x0024, client))
Devices[7].Update(1, self.phase_angle.strget())
#Domoticz.Log("Frequency : " + str(getmodbus(0x0046, client)) )
# Frequency
self.frequency.update(getmodbus(0x0046, client))
Devices[8].Update(1, self.frequency.strget())
# For Imported/Exported Energy (Active) and the last P1 Counter
power = self.active_power.get()
if power >= 0:
import_power = power
@ -264,45 +272,45 @@ class BasePlugin:
else:
export_power = 0
#Domoticz.Log("Import NRJ act : " + str(getmodbus(0x0048, client)) )
# Imported Energy (Active)
import_e = str(getmodbus(0x0048, client)*1000)
Devices[9].Update(1, sValue=str(import_power)+";"+import_e)
#Domoticz.Log("Export NRJ act : " + str(getmodbus(0x004a, client)) )
# Exported Energy (Active)
export_e = str(getmodbus(0x004a, client)*1000)
Devices[10].Update(1, sValue=str(export_power)+";"+export_e)
if Parameters["Mode5"] == "Moredata":
#Domoticz.Log("Total Demand Pwr : " + str(getmodbus(0x0054, client)) )
# Total Demand Powier (Active)
self.total_demand_power.update(getmodbus(0x0054, client))
Devices[13].Update(1, self.total_demand_power.strget())
#Domoticz.Log("Max Demand Pwr : " + str(getmodbus(0x0056, client)) )
# Maximum Total Demand Power (Active)
Devices[14].Update(1, str(getmodbus(0x0056, client)))
#Domoticz.Log("Input Demand Pwr : " + str(getmodbus(0x0058, client)) )
# Import Demand Power (Active)
self.import_demand_power.update(getmodbus(0x0058, client))
Devices[15].Update(1, self.import_demand_power.strget())
#Domoticz.Log("Max Input Demand Pwr : " + str(getmodbus(0x005a, client)) )
# Maximum Import Demand Power (Active)
Devices[16].Update(1, str(getmodbus(0x005a, client)))
#Domoticz.Log("Export Demand Pwr : " + str(getmodbus(0x005c, client)) )
# Export Demand Power (Active)
self.import_demand_power.update(getmodbus(0x0058, client))
Devices[17].Update(1, self.import_demand_power.strget())
#Domoticz.Log("Max Export Demand Pwr : " + str(getmodbus(0x005e, client)) )
# Maxium Export Demand Power (Active)
Devices[18].Update(1, str(getmodbus(0x005e, client)))
#Domoticz.Log("Total Demand Cur: " + str(getmodbus(0x0102, client)) )
# Total Demand Current
self.total_demand_current.update(getmodbus(0x0102, client))
Devices[19].Update(1, self.total_demand_current.strget())
#Domoticz.Log("Max Total Demand Cur: " + str(getmodbus(0x0108, client)) )
# Maxium Total Demand Current
Devices[20].Update(1, str(getmodbus(0x0108, client)))
#Domoticz.Log("Total Energy Act: " + str(getmodbus(0x0156, client)) )
# P1 Counter with import and export values
Devices[21].Update(1, sValue=import_e+";0;"+export_e+";0;"+str(import_power)+";"+str(export_power))