#!/usr/local/bin/python3
|
|
|
|
import urllib3
|
|
import json
|
|
import paho.mqtt.client as mqtt
|
|
import time
|
|
#import syslog
|
|
|
|
# Settings
|
|
from secret import ecodevice,gx,gxsn,chgbleu,chgblanc,chgrouge,minbleu,minblanc,minrouge
|
|
|
|
# Lancer ceci du 01 Oct au 31 mai
|
|
# une fois avant 22h / une fois apres 22h
|
|
|
|
# Don't touch that
|
|
# See : https://github.com/victronenergy/venus/wiki/dbus#settings
|
|
ESSwBL = 1 # ESS "Optimized with BatteryLife)
|
|
ESSwoBL = 10 # ESS "Optimized without BatteryLife)
|
|
|
|
# Log !
|
|
def loggerinfo(foo):
|
|
#syslog.syslog(syslog.LOG_INFO,foo)
|
|
print(foo)
|
|
|
|
# Setup MQTT Client
|
|
global client
|
|
|
|
def on_connect(client, userdata, flags, rc):
|
|
client.subscribe("$SYS/#")
|
|
global flagConntected
|
|
flagConntected = 1
|
|
loggerinfo("Broker connected.")
|
|
|
|
def on_message(client, userdata, msg):
|
|
loggerinfo(msg.topic+" "+str(msg.payload))
|
|
|
|
def on_publish(client, userdata, mid):
|
|
loggerinfo("Message Published.")
|
|
|
|
def on_disconnect(client, userdata, rc):
|
|
global flagConntected
|
|
flagConntected = 0
|
|
loggerinfo("Broker disconnected.")
|
|
|
|
client = mqtt.Client("clientdynTEMPO")
|
|
flagConntected = 0
|
|
client.on_connect = on_connect
|
|
client.on_message = on_message
|
|
client.on_publish = on_publish
|
|
client.on_disconnect = on_disconnect
|
|
#client.tls_set("venus-ca.crt")
|
|
#client.username_pw_set(username, password)
|
|
|
|
# Set the Maxmium SOC when schedule Charge
|
|
def setChargeSetpoint(chargepoint):
|
|
loggerinfo("Set charge setpoint: " + str(chargepoint) + " %")
|
|
if (chargepoint < 50) or (chargepoint > 100):
|
|
loggerinfo("Chargepoint should be between 50 to 100%")
|
|
else:
|
|
# Control ESS over MQTT
|
|
client.connect(gx, 1883, keepalive=60)
|
|
client.loop_start()
|
|
# Wait for connecting
|
|
while not flagConntected:
|
|
time.sleep(1)
|
|
client.publish("W/" + gxsn + "/settings/0/Settings/CGwacs/BatteryLife/Schedule/Charge/O/Soc", '{"value":' + str(chargepoint) + '}')
|
|
client.loop_stop()
|
|
|
|
# Set the Minimum Soc Limit
|
|
def setMinSocSetpoint(chargepoint):
|
|
loggerinfo("Set MinSoc setpoint: " + str(chargepoint) + " %")
|
|
if (chargepoint < 10) or (chargepoint > 40):
|
|
loggerinfo("Chargepoint should be between 50 to 100%")
|
|
else:
|
|
# Control ESS over MQTT
|
|
client.connect(gx, 1883, keepalive=60)
|
|
client.loop_start()
|
|
# Wait for connecting
|
|
while not flagConntected:
|
|
time.sleep(1)
|
|
client.publish("W/" + gxsn + "/settings/0/Settings/CGwacs/BatteryLife/MinimumSocLimit", '{"value":' + str(chargepoint) + '}')
|
|
client.loop_stop()
|
|
|
|
# Set ESS State (danger only 1 or 10 is ok)
|
|
# 1 = Optimized with Battery Life
|
|
# 10 = Optimized without battery life
|
|
# See https://github.com/victronenergy/venus/wiki/dbus#settings
|
|
def setESSstate(state):
|
|
loggerinfo("Set ESS State: " + str(state) )
|
|
# Security Checks
|
|
if (state == 1 or state == 10):
|
|
# Control ESS over MQTT
|
|
client.connect(gx, 1883, keepalive=60)
|
|
client.loop_start()
|
|
# Wait for connecting
|
|
while not flagConntected:
|
|
time.sleep(1)
|
|
client.publish("W/" + gxsn + "/settings/0/Settings/CGwacs/BatteryLife/State", '{"value":' + str(state) + '}')
|
|
lastChargeCondition = 1
|
|
client.loop_stop()
|
|
else:
|
|
loggerinfo(" -> not published")
|
|
|
|
# Setup EcoDevice
|
|
http = urllib3.PoolManager()
|
|
resp = http.request("GET", "http://"+ecodevice+"/api/xdevices.json?cmd=10")
|
|
|
|
if resp.status == 200:
|
|
teleinfo = json.loads(resp.data)
|
|
|
|
# Value of var today daynight
|
|
# HPJB = Bleu 0 1
|
|
# HCJB = Bleu 0 0
|
|
# HPJW = Blanc 1 1
|
|
# HCJW = Blanc 1 0
|
|
# HPJR = Rouge 2 1
|
|
# HCJR = Rouge 2 0
|
|
curtarif = teleinfo['T1_PTEC']
|
|
if curtarif == "HPJB":
|
|
today = 0
|
|
daynight = 1
|
|
elif curtarif == "HCJB":
|
|
today = 0
|
|
daynight = 0
|
|
elif curtarif == "HPJW":
|
|
today = 1
|
|
daynight = 1
|
|
elif curtarif == "HCJW":
|
|
today = 1
|
|
daynight = 0
|
|
elif curtarif == "HPJR":
|
|
today = 2
|
|
daynight = 1
|
|
elif curtarif == "HCJR":
|
|
today = 2
|
|
daynight = 0
|
|
else:
|
|
today = 0
|
|
daynight = 0
|
|
|
|
# Value of var tomorrow
|
|
# ---- = Bleu 0
|
|
# BLEU = Bleu 0
|
|
# BLAN = Blanc 1
|
|
# ROUG = Rouge 2
|
|
demaintarif = teleinfo['T1_DEMAIN']
|
|
if demaintarif == "----":
|
|
tomorrow = 0
|
|
elif demaintarif == "BLEU":
|
|
tomorrow = 0
|
|
elif demaintarif == "BLANC":
|
|
tomorrow = 1
|
|
elif demaintarif == "ROUG":
|
|
tomorrow = 2
|
|
else:
|
|
tomorrow=0
|
|
|
|
|
|
loggerinfo("Current tarif: " + curtarif + " ("+str(today)+" / "+str(daynight) + ")")
|
|
loggerinfo("Demain tarif: " + demaintarif + " ("+str(tomorrow)+")")
|
|
|
|
# daynight : 1 = jour / 0 nuit
|
|
# Today Tomorrow Daynight Action
|
|
# 0 0 O Rien
|
|
# 0 0 1 Rien
|
|
# 0 1 0 Rien
|
|
# 0 1 1 Charge 90%
|
|
# 0 2 0 SocMin 25% / Batterlife Off
|
|
# 0 2 1 Charge 95%
|
|
# 1 0 0 SocMin 30%
|
|
# 1 0 1 Charge 80%
|
|
# 1 1 0 Rien
|
|
# 1 1 1 Rien
|
|
# 1 2 0 SocMin 25% / Batterlife Off
|
|
# 1 2 1 Charge 95%
|
|
# 2 0 0 SocMin 30% / Batterlife On
|
|
# 2 0 1 Charge 80%
|
|
# 2 1 0 SocMin 30% / Batterlife On
|
|
# 2 1 1 Charge 90%
|
|
# 2 2 0 Rien
|
|
# 2 2 1 Rien
|
|
#today = 1
|
|
#tomorrow = 0
|
|
#daynight = 0
|
|
if today == tomorrow:
|
|
loggerinfo ("Rien a faire on sort")
|
|
elif today == 0: # Bleu
|
|
if tomorrow == 1: # Blanc
|
|
if daynight == 1:
|
|
loggerinfo ("Charge 90%")
|
|
setChargeSetpoint(chgblanc)
|
|
elif tomorrow == 2: # Rouge
|
|
if daynight == 1:
|
|
loggerinfo ("Charge 95%")
|
|
setChargeSetpoint(chgrouge)
|
|
else:
|
|
loggerinfo ("SocMin 25%")
|
|
setMinSocSetpoint(minrouge)
|
|
loggerinfo ("Battery life OFF")
|
|
setESSstate(ESSwoBL)
|
|
elif today == 1: # Blanc
|
|
if tomorrow == 0: # Bleu
|
|
if daynight == 1:
|
|
loggerinfo ("Charge 80%")
|
|
setChargeSetpoint(chgbleu)
|
|
else:
|
|
loggerinfo ("SocMin 30%")
|
|
setMinSocSetpoint(minbleu)
|
|
elif tomorrow == 2: # Rouge
|
|
if daynight == 1:
|
|
loggerinfo ("Charge 95%")
|
|
setChargeSetpoint(chgrouge)
|
|
else:
|
|
loggerinfo ("SocMin 25%")
|
|
setMinSocSetpoint(minrouge)
|
|
loggerinfo ("Battery life OFF")
|
|
setESSstate(ESSwoBL)
|
|
elif today == 2: # Rouge
|
|
if tomorrow == 0: # Bleu
|
|
if daynight == 1:
|
|
loggerinfo ("Charge 80%")
|
|
setChargeSetpoint(chgbleu)
|
|
else:
|
|
loggerinfo ("SocMin 30%")
|
|
setChargeSetpoint(chgbleu)
|
|
loggerinfo ("Battery life ON")
|
|
setESSstate(ESSwBL)
|
|
elif tomorrow == 1: # Blanc
|
|
if daynight == 1:
|
|
loggerinfo ("Charge 90%")
|
|
setChargeSetpoint(chgblanc)
|
|
else:
|
|
loggerinfo ("SocMin 30%")
|
|
setMinSocSetpoint(minblanc)
|
|
loggerinfo ("Battery life ON")
|
|
setESSstate(ESSwBL)
|
|
|
|
# Voir code : https://github.com/xbeaudouin/dynamic-ess
|
|
# ET : https://github.com/victronenergy/venus/wiki/dbus#settings
|