Changed device type for temperature
This commit is contained in:
29
plugin.py
29
plugin.py
@ -210,7 +210,7 @@ THREE_PHASE_INVERTER = [
|
||||
[Unit.CURRENT_DC, "DC Current", 0xF3, 0x17, 0x00, {}, "current_dc", "current_dc_scale", "{:.2f}", None, None, None ],
|
||||
[Unit.VOLTAGE_DC, "DC Voltage", 0xF3, 0x08, 0x00, {}, "voltage_dc", "voltage_dc_scale", "{:.2f}", None, None, Average() ],
|
||||
[Unit.POWER_DC, "DC Power", 0xF8, 0x01, 0x00, {}, "power_dc", "power_dc_scale", "{:.2f}", None, None, Average() ],
|
||||
[Unit.TEMPERATURE, "Temperature", 0x50, 0x05, 0x00, {}, "temperature", "temperature_scale", "{:.2f}", None, None, Maximum() ]
|
||||
[Unit.TEMPERATURE, "Temperature", 0xF3, 0x05, 0x00, {}, "temperature", "temperature_scale", "{:.2f}", None, None, Maximum() ]
|
||||
]
|
||||
|
||||
#
|
||||
@ -457,6 +457,33 @@ class BasePlugin:
|
||||
if unit[Column.MATH]:
|
||||
unit[Column.MATH].set_max_samples(self.max_samples)
|
||||
|
||||
|
||||
# We updated some device types over time.
|
||||
# Let's make sure that we have the correct type setup.
|
||||
|
||||
for unit in self._LOOKUP_TABLE:
|
||||
if unit[Column.ID] in Devices:
|
||||
device = Devices[unit[Column.ID]]
|
||||
|
||||
if (device.Type != unit[Column.TYPE] or
|
||||
device.SubType != unit[Column.SUBTYPE] or
|
||||
device.SwitchType != unit[Column.SWITCHTYPE] or
|
||||
device.Options != unit[Column.OPTIONS]):
|
||||
|
||||
Domoticz.Log("Updating device \"{}\"".format(device.Name))
|
||||
|
||||
nValue = device.nValue
|
||||
sValue = device.sValue
|
||||
|
||||
device.Update(
|
||||
Type=unit[Column.TYPE],
|
||||
Subtype=unit[Column.SUBTYPE],
|
||||
Switchtype=unit[Column.SWITCHTYPE],
|
||||
Options=unit[Column.OPTIONS],
|
||||
nValue=nValue,
|
||||
sValue=sValue
|
||||
)
|
||||
|
||||
# Add missing devices if needed.
|
||||
|
||||
if self.add_devices:
|
||||
|
||||
Reference in New Issue