Added Alert device : Grid lost.

This commit is contained in:
2022-09-28 22:48:42 +02:00
parent 788a0de2c9
commit 0292bcf8d8

View File

@ -192,8 +192,8 @@ class BasePlugin:
if 8 not in Devices:
Options = { "Custom": "1;Hz" }
Domoticz.Device(Name="Frequency OUT L1", Unit=8, TypeName="Custom", Used=0, Options=Options).Create()
#if 9 not in Devices:
# Grid lost Alarm
if 9 not in Devices:
Domoticz.Device(Name="Grid Lost", Unit=9, TypeName="Alert", Used=0).Create()
# Battery
if 20 not in Devices:
@ -260,6 +260,7 @@ class BasePlugin:
Devices[6].Update(1, "0")
Devices[7].Update(1, "0")
Devices[8].Update(1, "0")
Devices[9].Update(1, "0")
# Ac In Voltage
data = client.read_holding_registers(3, 1)
@ -389,6 +390,17 @@ class BasePlugin:
Domoticz.Debug(" = {}".format(value))
Devices[8].Update(1, str(value))
# Grid lost
data = client.read_holding_registers(64, 1)
Domoticz.Debug("Data from register 64: "+str(data))
decoder = BinaryPayloadDecoder.fromRegisters(data, byteorder=Endian.Big, wordorder=Endian.Big)
value = decoder.decode_16bit_int()
if value == 0:
Devices[9].Update(nValue=value, sValue="Ok")
elif value == 2:
Devices[9].Update(nValue=value, sValue="Alert - Grid Lost")
else:
Devices[9].Update(nValue=3, sValue="Unknown state ?")
# Multiplus devices