Initial pluging for Victron Energy MPPT with GX + Modbus
This commit is contained in:
304
mppt/plugin.py
Normal file
304
mppt/plugin.py
Normal file
@ -0,0 +1,304 @@
|
||||
#!/usr/bin/env python
|
||||
"""
|
||||
Victron Energy MPPT plugin
|
||||
Author: Xavier Beaudouin
|
||||
Requirements:
|
||||
1. multiplus + GX
|
||||
2. modbus over TCP adapter like PW21
|
||||
3. pymodbus AND pymodbusTCP
|
||||
"""
|
||||
"""
|
||||
<plugin key="VictronEnergy_GX_MPPT" name="Victron Energy MPPT over GX + Modbus" author="Xavier Beaudouin" version="0.0.1" externallink="https://github.com/xbeaudouin/victron-energy-domoticz/mppt">
|
||||
<params>
|
||||
<param field="Address" label="GX IP Address" width="150px" required="true" />
|
||||
<param field="Port" label="GX Modbus Port Number" width="100px" required="true" default="502" />
|
||||
<param field="Mode3" label="Modbus address" width="100px" required="true" default="229" />
|
||||
<param field="Mode6" label="Debug" width="100px">
|
||||
<options>
|
||||
<option label="True" value="Debug"/>
|
||||
<option label="False" value="Normal" default="true" />
|
||||
</options>
|
||||
</param>
|
||||
</params>
|
||||
</plugin>
|
||||
"""
|
||||
|
||||
import Domoticz
|
||||
import sys
|
||||
|
||||
sys.path.append('/usr/local/lib/python3.4/dist-packages')
|
||||
sys.path.append('/usr/local/lib/python3.5/dist-packages')
|
||||
sys.path.append('/usr/local/lib/python3.6/dist-packages')
|
||||
sys.path.append('/usr/local/lib/python3.7/dist-packages')
|
||||
sys.path.append('/usr/local/lib/python3.8/dist-packages')
|
||||
sys.path.append('/usr/local/lib/python3.9/dist-packages')
|
||||
|
||||
import pymodbus
|
||||
|
||||
from pyModbusTCP.client import ModbusClient
|
||||
from pymodbus.constants import Endian
|
||||
from pymodbus.payload import BinaryPayloadDecoder
|
||||
|
||||
#
|
||||
# Domoticz shows graphs with intervals of 5 minutes.
|
||||
# When collecting information from the inverter more frequently than that, then it makes no sense to only show the last value.
|
||||
#
|
||||
# The Average class can be used to calculate the average value based on a sliding window of samples.
|
||||
# The number of samples stored depends on the interval used to collect the value from the inverter itself.
|
||||
#
|
||||
|
||||
class Average:
|
||||
|
||||
def __init__(self):
|
||||
self.samples = []
|
||||
self.max_samples = 30
|
||||
|
||||
def set_max_samples(self, max):
|
||||
self.max_samples = max
|
||||
if self.max_samples < 1:
|
||||
self.max_samples = 1
|
||||
|
||||
def update(self, new_value, scale = 0):
|
||||
self.samples.append(new_value * (10 ** scale))
|
||||
while (len(self.samples) > self.max_samples):
|
||||
del self.samples[0]
|
||||
|
||||
Domoticz.Debug("Average: {} - {} values".format(self.get(), len(self.samples)))
|
||||
|
||||
def get(self):
|
||||
return sum(self.samples) / len(self.samples)
|
||||
|
||||
#
|
||||
# Domoticz shows graphs with intervals of 5 minutes.
|
||||
# When collecting information from the inverter more frequently than that, then it makes no sense to only show the last value.
|
||||
#
|
||||
# The Maximum class can be used to calculate the highest value based on a sliding window of samples.
|
||||
# The number of samples stored depends on the interval used to collect the value from the inverter itself.
|
||||
#
|
||||
|
||||
class Maximum:
|
||||
|
||||
def __init__(self):
|
||||
self.samples = []
|
||||
self.max_samples = 30
|
||||
|
||||
def set_max_samples(self, max):
|
||||
self.max_samples = max
|
||||
if self.max_samples < 1:
|
||||
self.max_samples = 1
|
||||
|
||||
def update(self, new_value, scale = 0):
|
||||
self.samples.append(new_value * (10 ** scale))
|
||||
while (len(self.samples) > self.max_samples):
|
||||
del self.samples[0]
|
||||
|
||||
Domoticz.Debug("Maximum: {} - {} values".format(self.get(), len(self.samples)))
|
||||
|
||||
def get(self):
|
||||
return max(self.samples)
|
||||
|
||||
# Plugin itself
|
||||
class BasePlugin:
|
||||
#enabled = False
|
||||
def __init__(self):
|
||||
# Voltage for last 5 minutes
|
||||
self.voltage=Average()
|
||||
# Current for last 5 minutes
|
||||
self.current=Average()
|
||||
# Power factor for last 5 minutes
|
||||
self.power=Average()
|
||||
|
||||
return
|
||||
|
||||
def onStart(self):
|
||||
try:
|
||||
Domoticz.Log("Victron Energy MPPT over GX + Modbus loaded!, using python v" + sys.version[:6] + " and pymodbus v" + pymodbus.__version__)
|
||||
except:
|
||||
Domoticz.Log("Victron Energy MPPT over GX + Modbus loaded!")
|
||||
|
||||
# Check dependancies
|
||||
try:
|
||||
if (float(Parameters["DomoticzVersion"][:6]) < float("2020.2")): Domoticz.Error("WARNING: Domoticz version is outdated or not supported. Please update!")
|
||||
if (float(sys.version[:1]) < 3): Domoticz.Error("WARNING: Python3 should be used !")
|
||||
if (float(pymodbus.__version__[:3]) < float("2.3")): Domoticz.Error("WARNING: pymodbus version is outdated, please update!")
|
||||
except:
|
||||
Domoticz.Error("Warning ! Dependancies could not be checked !")
|
||||
|
||||
# Parse parameters
|
||||
|
||||
# Debug
|
||||
if Parameters["Mode6"] == "Debug":
|
||||
Domoticz.Debugging(1)
|
||||
else:
|
||||
Domoticz.Debugging(0)
|
||||
|
||||
self.IPAddress = Parameters["Address"]
|
||||
self.IPPort = Parameters["Port"]
|
||||
self.MBAddr = int(Parameters["Mode3"])
|
||||
|
||||
Domoticz.Debug("Query IP " + self.IPAddress + ":" + str(self.IPPort) +" on device : "+str(self.MBAddr))
|
||||
|
||||
# Create the devices if they does not exists
|
||||
# TODO: refactor this.
|
||||
if 1 not in Devices:
|
||||
Domoticz.Device(Name="Voltage", Unit=1, TypeName="Voltage", Used=0).Create()
|
||||
if 2 not in Devices:
|
||||
Domoticz.Device(Name="Current", Unit=2, TypeName="Current (Single)", Used=0).Create()
|
||||
if 3 not in Devices:
|
||||
Options = { "Custom": "1;W" }
|
||||
Domoticz.Device(Name="Power", Unit=3, TypeName="Custom", Used=0, Options=Options).Create()
|
||||
if 4 not in Devices:
|
||||
Domoticz.Device(Name="Total Energy", Unit=4,Type=0xfa, Subtype=0x01, Used=0).Create()
|
||||
|
||||
return
|
||||
|
||||
|
||||
def onStop(self):
|
||||
Domoticz.Debugging(0)
|
||||
|
||||
def onConnect(self, Connection, Status, Description):
|
||||
Domoticz.Log("onConnect called")
|
||||
return
|
||||
|
||||
def onMessage(self, Connection, Data):
|
||||
Domoticz.Log("onMessage called")
|
||||
|
||||
def onCommand(self, Unit, Command, Level, Hue):
|
||||
Domoticz.Log("onCommand called for Unit " + str(Unit) + ": Parameter '" + str(Command) + "', Level: " + str(Level))
|
||||
|
||||
def onNotification(self, Name, Subject, Text, Status, Priority, Sound, ImageFile):
|
||||
Domoticz.Log("Notification: " + Name + "," + Subject + "," + Text + "," + Status + "," + str(Priority) + "," + Sound + "," + ImageFile)
|
||||
|
||||
def onDisconnect(self, Connection):
|
||||
Domoticz.Log("onDisconnect called")
|
||||
|
||||
def onHeartbeat(self):
|
||||
Domoticz.Debug(" Interface : IP="+self.IPAddress +", Port="+str(self.IPPort)+" ID="+str(self.MBAddr))
|
||||
try:
|
||||
client = ModbusClient(host=self.IPAddress, port=self.IPPort, unit_id=self.MBAddr, auto_open=True, auto_close=True, timeout=2)
|
||||
except:
|
||||
Domoticz.Error("Error connecting to TCP/Interface on address : "+self.IPaddress+":"+str(self.IPPort))
|
||||
# Set value to 0 -> Error on all devices
|
||||
Devices[1].Update(1, "0")
|
||||
Devices[2].Update(1, "0")
|
||||
Devices[3].Update(1, "0")
|
||||
Devices[4].Update(1, "0")
|
||||
|
||||
# TODO: catch errors
|
||||
total_e = "0"
|
||||
power = "0"
|
||||
|
||||
# Voltage
|
||||
data = client.read_holding_registers(776, 1)
|
||||
Domoticz.Debug("Data from register 776: "+str(data))
|
||||
# Unsigned 16
|
||||
decoder = BinaryPayloadDecoder.fromRegisters(data, byteorder=Endian.Big, wordorder=Endian.Big)
|
||||
# Value
|
||||
value = decoder.decode_16bit_int()
|
||||
# Scale factor / 100
|
||||
value = round (value / 100.0, 3)
|
||||
Domoticz.Debug("Value after conversion : "+str(value))
|
||||
Domoticz.Debug("-> Calculating average")
|
||||
self.voltage.update(value)
|
||||
value = self.voltage.get()
|
||||
Domoticz.Debug(" = {}".format(value))
|
||||
Devices[1].Update(1, str(value))
|
||||
|
||||
# Current
|
||||
data = client.read_holding_registers(777, 1)
|
||||
Domoticz.Debug("Data from register 777: "+str(data))
|
||||
# Unsigned 16
|
||||
decoder = BinaryPayloadDecoder.fromRegisters(data, byteorder=Endian.Big, wordorder=Endian.Big)
|
||||
# Value
|
||||
value = decoder.decode_16bit_int()
|
||||
# Scale factor / 10.0
|
||||
value = round (value / 10.0, 3)
|
||||
Domoticz.Debug("Value after conversion : "+str(value))
|
||||
Domoticz.Debug("-> Calculating average")
|
||||
self.current.update(value)
|
||||
value = self.current.get()
|
||||
Domoticz.Debug(" = {}".format(value))
|
||||
Devices[2].Update(1, str(value))
|
||||
|
||||
# Power
|
||||
data = client.read_holding_registers(789, 1)
|
||||
Domoticz.Debug("Data from register 789: "+str(data))
|
||||
# Unsigned 16
|
||||
decoder = BinaryPayloadDecoder.fromRegisters(data, byteorder=Endian.Big, wordorder=Endian.Big)
|
||||
# Value
|
||||
value = decoder.decode_16bit_int()
|
||||
# Scale factor / 10.0
|
||||
value = round (value / 10.0, 3)
|
||||
Domoticz.Debug("Value after conversion : "+str(value))
|
||||
Domoticz.Debug("-> Calculating average")
|
||||
self.power.update(value)
|
||||
value = self.power.get()
|
||||
Domoticz.Debug(" = {}".format(value))
|
||||
Devices[3].Update(1, str(value))
|
||||
power = str(value)
|
||||
|
||||
# Total Energy
|
||||
data = client.read_holding_registers(790, 1)
|
||||
Domoticz.Debug("Data from register 790: "+str(data))
|
||||
# Unsigned 32
|
||||
decoder = BinaryPayloadDecoder.fromRegisters(data, byteorder=Endian.Big, wordorder=Endian.Big)
|
||||
# Value
|
||||
value = decoder.decode_16bit_int()
|
||||
Domoticz.Debug(" = {}".format(value))
|
||||
# Scale * 100 (to have Wh)
|
||||
total_e = str(value*100)
|
||||
|
||||
|
||||
# Do insert data on counters
|
||||
Devices[4].Update(1, sValue=total_e+";0;0;0;"+power+";0")
|
||||
|
||||
|
||||
global _plugin
|
||||
_plugin = BasePlugin()
|
||||
|
||||
def onStart():
|
||||
global _plugin
|
||||
_plugin.onStart()
|
||||
|
||||
def onStop():
|
||||
global _plugin
|
||||
_plugin.onStop()
|
||||
|
||||
def onConnect(Connection, Status, Description):
|
||||
global _plugin
|
||||
_plugin.onConnect(Connection, Status, Description)
|
||||
|
||||
def onMessage(Connection, Data):
|
||||
global _plugin
|
||||
_plugin.onMessage(Connection, Data)
|
||||
|
||||
def onCommand(Unit, Command, Level, Hue):
|
||||
global _plugin
|
||||
_plugin.onCommand(Unit, Command, Level, Hue)
|
||||
|
||||
def onNotification(Name, Subject, Text, Status, Priority, Sound, ImageFile):
|
||||
global _plugin
|
||||
_plugin.onNotification(Name, Subject, Text, Status, Priority, Sound, ImageFile)
|
||||
|
||||
def onDisconnect(Connection):
|
||||
global _plugin
|
||||
_plugin.onDisconnect(Connection)
|
||||
|
||||
def onHeartbeat():
|
||||
global _plugin
|
||||
_plugin.onHeartbeat()
|
||||
|
||||
# Generic helper functions
|
||||
def DumpConfigToLog():
|
||||
for x in Parameters:
|
||||
if Parameters[x] != "":
|
||||
Domoticz.Debug( "'" + x + "':'" + str(Parameters[x]) + "'")
|
||||
Domoticz.Debug("Device count: " + str(len(Devices)))
|
||||
for x in Devices:
|
||||
Domoticz.Debug("Device: " + str(x) + " - " + str(Devices[x]))
|
||||
Domoticz.Debug("Device ID: '" + str(Devices[x].ID) + "'")
|
||||
Domoticz.Debug("Device Name: '" + Devices[x].Name + "'")
|
||||
Domoticz.Debug("Device nValue: " + str(Devices[x].nValue))
|
||||
Domoticz.Debug("Device sValue: '" + Devices[x].sValue + "'")
|
||||
Domoticz.Debug("Device LastLevel: " + str(Devices[x].LastLevel))
|
||||
return
|
||||